NMT-204

  • designed for measurement of moisture in the hopper when the detection unit is surrounded from all sides by measured material
  • the detection system is based on the slow down of the neutron radiation on hydrogen atoms
  • ideal for continuous measurement of moisture in bulk materials
  • measuring humidity of large quantities of material
  • independent of temperature, colour and granulometry of material
  • accurate average results, even in a heterogeneous distribution of moisture
  • operationally highly reliable and trouble-free
  • As a source of neutrons is always used 241Am-Be in max. activity 3.7 GBq
  • Power supply: 24 V DC
  • Electric current: 315 mA
  • range of working temperature:
    • detection unit -20 °C až +150 °C
    • the entire device -15 °C až +70 °C
  • cover:
    • unit of preamplifier with high voltage source IP66
    • evaluation unit IP 54
  • dimensions and fastening
    • detection unit (according to used detector) mostly diameter 22x210 mm
    • unit of preamplifier with high voltage source 255x180x90 mm
    • fastening 165x239 mm, M4
    • evaluation unit 120x200x300 mm
    • fastening 160x260, M6